Review available utility records and choose suitable methods, such as ground-penetrating radar or electromagnetic locating, according to targets and site conditions.
Detection accuracy depends on depth, material, soil properties and interference. A negative survey does not prove that utilities are absent; controlled verification and coordination with network owners may be required.
Share the survey boundaries, expected utilities and excavation plan to define suitable methods and usable deliverables.
Ground penetrating radar responds to electromagnetic contrasts; penetration may be limited in conductive soils. Electromagnetic locating performance depends on utility material and access for tracing. Select methods according to site conditions and anticipated utilities.
Subsurface utility engineering distinguishes records, visible features, geophysical detection and direct verification. An anomaly-free survey does not guarantee absence of utilities. Follow excavation permits and arrange safe verification at critical conflicts.
Technical references
International technical references are informative; applicable Egyptian codes and project specifications govern the work.
General guidance; project-specific assessment is required.